Connector - SCSI-III External Hi D-Sub (Single-ended)68 PIN HI-DENSITY D-SUB FEMALE at the controller & devices. 68 PIN HI-DENSITY D-SUB MALE at the cable. | (at the controller & devices). |  | (To the cable). |
| Pin | Name | Direction | Description |
|---|
| 1-16 | GND | --- | Ground | | 17 | TERMPWR | --- | Termination Power | | 18 | TERMPWR | --- | Termination Power | | 19 | res | --- | reserved | | 20-34 | GND | --- | Ground | | 35 | DB12 | --- | Data Bus 12 | | 36 | DB13 | --- | Data Bus 13 | | 37 | DB14 | --- | Data Bus 14 | | 38 | DB15 | --- | Data Bus 15 | | 39 | DPB1 | --- | Data Parity (odd Parity) | | 40 | DB0 | --- | Data Bus 0 | | 41 | DB1 | --- | Data Bus 1 | | 42 | DB2 | --- | Data Bus 2 | | 43 | DB3 | --- | Data Bus 3 | | 44 | DB4 | --- | Data Bus 4 | | 45 | DB5 | --- | Data Bus 5 | | 46 | DB6 | --- | Data Bus 6 | | 47 | DB7 | --- | Data Bus 7 | | 48 | DPB | --- | Data Parity (odd Parity) | | 49 | GND | --- | Ground | | 50 | GND | --- | Ground | | 51 | TERMPWR | --- | Termination Power | | 52 | TERMPWR | --- | Termination Power | | 53 | res | --- | reserved | | 54 | GND | --- | Ground | | 55 | /ATN | Input | Attention | | 56 | GND | --- | Ground | | 57 | /BSY | --- | Busy | | 58 | /ACK | Input | Acknowledge | | 59 | /RST | --- | Reset | | 60 | /MSG | Output | Message | | 61 | /SEL | --- | Select | | 62 | /C/D | Output | Control/Data | | 63 | /REQ | Output | Request | | 64 | /I/O | Output | Input/Output | | 65 | DB8 | --- | Data Bus 8 | | 66 | DB9 | --- | Data Bus 9 | | 67 | DB10 | --- | Data Bus 10 | | 68 | DB11 | --- | Data Bus 11 |
Note: Direction is Device relative Bus (other Devices).
|